3.2 Simplified operation of the VF-AS1
On of three operation modes can be selected: terminal board operation, operation panel and combination of both.
⇒ For other operation modes, refer to Section 5.5.
Terminal board mode
:Operation by means of external signals
Operation panel mode :Operation by pressing keys on the operation panel
Operation panel + terminal board mode :Frequency, start/stop signals can be
sent individually from the operating panel and terminal board.
3.2.1 Terminal board operation
In this mode, the motor is started or stopped according to the ON/OFF signal to input terminals (such as the ST
terminal and the F terminal). Also, the frequency is set according to the potentiometer/voltage/current signals to analog
input terminals (such as the RR/S4 terminal, VI/II terminal and RX terminal).
⇒ For more details, refer to Section 7.
■ Example of standard connection
Motor
IM
CCA
RX
VI/II
RR/S4
PP
F
R
CC
R/L1
U/T1
External potentiometer (or voltage signal RR/S4-CCA:0 to 10V)
Volta
e si
nal:-10~+10Vdc
Voltage signal:0~10Vdc
or current signal:4(0)~20mAdc
ON:Forward run, OFF:Deceleration stop
Stand-by:ON:Stand-by, OFF:Coast stop
ST
ON:Reverse run, OFF:Deceleration stop
V/T2
W/T3
S/L2
T/L3
Power
supply
MCCB
Inverter
■
Run/Deceleration stop
Selecting a command mode for basic parameters
EOQF
=
(standard default setting)
and are connected: Forward run
and are disconnected: Deceleration stop
(When terminals and are electrically connected)
F
CC
F
CC
CC
ST
Fre
uenc
ON
OFF
ON
OFF
F-CC
Deceleration
ST-CC
+
For coast stop
Open the connection between ST and CC
when stopping the motor in the state
described at left. The monitor on the inverte
at this time will display
QHH
.
Motor
s
eed
ON
OFF
ON
OFF
F-CC
ST-CC
Coast stop