E6581301
F-33
6
[Timing chart (example)]
Set frequency
Commercial power/inverter switching frequency
H
MC output for inverter operation
Commercial power/inverter switching output 1
(P24-OUT1)
MC output for commercial power operation
Commercial power/inverter switching output 2
(P24-OUT2)
Commercial
p
ower switchin
g
si
g
nal
(
S3-CC
)
ON
Commercial power-side switching
waiting time H
Inverter-side switching waiting
time H
Detection time
Commercial power switching frequency
holding time H
ON
ON
ON
Operation standby signal (ST-CC)
ON
Commercial power switching signal S3-CC ON : Commercial power operation
Commercial power switching signal S3-CC OFF : Inverter operation
Note:If ST-CC is opened, switching cannot be operated normally.
Title Function Adjustment range Example of setting
H
Commercial power/inverter switching output selection
~ or
H Commercial power/inverter switching frequency ~WNHz Power supply frequency etc.
H Inverter-side switching waiting time ~
sec.
According to model
H Commercial power-side switching waiting time ~
sec.

H
Commercial power switching frequency holding time
~
sec.

H Input terminal function selection 7 (S3) ~

(Commercial power switching)
H Output terminal function selection 1 (OUT1) ~ 

(Commercial power/inverter
switching output 1)
H Output terminal function selection 2 (OUT2) ~ 

(Commercial power/inverter
switching output 2)
- Warning -
• When switching to commercial power, make sure that the direction in which the motor rotates when operated
on commercial power agrees with the forward direction when operated via the inverter.
• Do not select any option (
H
=
) of
H
(reverse rotation prohibition selection) that prohibits forward
rotation. Or it becomes impossible to switch to commercial power, because the motor cannot rotate in the
forward direction.
6.20 PID control
H : PID control switching
H
:
PID control feedback control signal selection
H : Delay filter
H
: Proportional (P) gain
H
: Integral (I) gain
H
: PID deviation upper limit
H
: PID deviation lower limit
H
: Differential (D) gain
H
: Process upper limit
H
: Process lower limit
H
: PID control waiting time
H
: PID output upper limit
H
: PID output lower limit
H
: Process increasing rate
(speed type PID control)
H
: Process decreasing rate
(speed type PID control)
For details, see Instruction Manual (E6581329) specified in Section 6.41.