Vista de pagina 258
K-21
E6581301
11
[23] Pattern operation [2/3]
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
settin
g
unit
(
Panel/Communi
cation)
Default
settin
g
Write durin
g
runnin
g
Speed
control
Torq ue
control
PM
control
V/f Constan
t
Reference
H 0540 Speed 1 operation time
0.1~6000 (The unit depends on the setting of
H.)
6000:Infinite
(
depends on the stop tri
gg
er entered
)
0.1/0.1 5.0 Enabled / - ●●6. 31
H 0541 Speed 2 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0542 Speed 3 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0543 Speed 4 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0544 Speed 5 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0545 Speed 6 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0546 Speed 7 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0547 Speed 8 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0548 Speed 9 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0549 Speed 10 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0550 Speed 11 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0551 Speed 12 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0552 Speed 13 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0553 Speed 14 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0554 Speed 15 operation time Ditto 0.1/0.1 5.0 Enabled / - ●●6. 31
H 0560
Preset speed operation mode
selection
0:Preset speed operation with no mode
1:Preset speed operation with mode
1/1 0 Disabled / - ●●5. 12
H 0561
Preset speed operation
frequency 1 operation mode
0:Forward run
+1:Reverse run
+2:Acceleration/deceleration switching signal 1
+4:Acceleration/deceleration switching signal 2
+8:V/f switching signal 1
+16:V/f switching signal 2
+32:Torque limit switching signal 1
+64:Torque limit switching signal 2
1/1 0 Disabled / - ●●5. 12
H 0562
Preset speed operation
frequency 2 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0563
Preset speed operation
frequency 3 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0564
Preset speed operation
frequency 4 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0565
Preset speed operation
frequency 5 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0566
Preset speed operation
frequency 6 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0567
Preset speed operation
frequency 7 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0568
Preset speed operation
frequency 8 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
H 0569
Preset speed operation
frequency 9 operation mode
Ditto 1/1 0 Disabled / - ●●5. 12
Sensorless vector/vector with sensor (:Effective, -:Ineffective)