K-10
E6581301
11
[7] Operation frequency
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
settin
unit
Panel/Communi
cation)
Default
settin
Write durin
runnin
Speed
control
Torq ue
control
PM
control
V/f Reference
H 0240 Starting frequency setting 0.0~10.0Hz 0.1/0.01 0.1 Enabled ●/● - ●●6. 7. 1
H 0241 Operation start frequency 0.0~HJ Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 7. 2
H 0242
Operation start frequency
hysteresis
0.0~30.0Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 7. 2
H 0243 Stop frequency setting 0.0~30.0Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 7. 1
H 0244
Frequency command dead
band
0.0~5.0Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 7. 3
[8] DC braking
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
settin
unit
Panel/Communi
cation)
Default
settin
Write durin
runnin
Speed
control
Torq ue
control
PM
control
V/f Reference
H 0250 DC braking start frequency 0.0~120.0Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 8. 1
H 0251 DC braking current 0~100% 1/1 50 Enabled ●/● - ●●6. 8. 1
H 0252 DC braking time 0.0~20.0 sec. 0.1/0.1 1.0 Enabled ●/● - ●●6. 8. 1
H 0253
Forward/reverse DC braking
priority control
0:OFF, 1:ON 1/1 0 Enabled ●/● - ●●6. 8. 1
H 0254 Motor shaft fixing control 0:Disabled, 1:Enabled 1/1 0 Enabled ●/● - ●●6. 8. 2
H 0255 0Hz command output selection 0:Default (DC braking), 1:0Hz command 1/1 0 Enabled -/● - ●●6. 8. 3
H 0256
Time limit for lower-limit
frequency operation
0.0:Disabled, 0.1~600.0 sec. 0.1/0.1 0.0 Enabled ●/●●/●●●6. 9
[9] Jogging operation
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
settin
unit
Panel/Communi
cation)
Default
settin
Write durin
runnin
Speed
control
Torq ue
control
PM
control
V/f Reference
H 0260 Jog run frequency H~20.0Hz 0.1/0.01 5.0 Enabled ●/● - ●●6. 10
H 0261 Jog run stop pattern
0:Deceleration stop, 1:Coast stop, 2:DC braking
stop
1/1 0 Disabled ●/● - ●●6. 10
H 0262
Operation panel jog run
operation mode
0:OFF, 1:Operation panel jog run mode enabled 1/1 0 Enabled ●/● - ●●6. 10
H 0264
Input from external contacts -
UP response time
0.0~10.0 sec. 0.1/0.1 0.1 Enabled ●/● - ●●6. 11
H 0265
Input from external contacts -
UP frequency step
0.0~HJ Hz 0.1/0.01 0.1 Enabled ●/● - ●●6. 11
H 0266
Input from external contacts -
DOWN response time
0.0~10.0 sec. 0.1/0.1 0.1 Enabled ●/● - ●●6. 11
H 0267
Input from external contacts -
DOWN frequency step
0.0~HJ Hz 0.1/0.01 0.1 Enabled ●/● - ●●6. 11
H 0268 Initial UP/DOWN frequency NN~WN Hz 0.1/0.01 0.0 Enabled ●/● - ●●6. 11
H 0269
Initial up/down frequency
rewriting
0:Not rewrite, 1:Rewrite H when power is
turned off
1/1 1 Enabled ●/● - ●●6. 11
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)