K-41
E6581301
11
[Input terminal function setting (1/2)] Sensorless vector/vector with sensor (●: valid, -: invalid)
Positive
logic
Negative
logic
Function
Speed
control
Torq ue
control
PM control V/f EOQF= H= Reference
0 1 No function is assigned ●/●●/●● ● --
2 3 F: Forward run command ●/●●/●● ● ● -
4 5 R: Reverse run command ●/●●/●● ● ● -
6 7 ST: Standby ●/●●/●● ● *1 -
8 9 RES: Reset ●/●●/●● ● *2 -
10 11 S1: Preset speed 1 ●/● - ●●●-
12 13 S2: Preset speed 2 ●/● - ●●● -
14 15 S3: Preset speed 3 ●/● - ●●● -
16 17 S4: Preset speed 4 ●/● - ●●● -
18 19 Jog run ●/● - ●●●●
20 21 Emergency stop ●/●●/●● ● *2 -
22 23 DC braking ●/● - ●●●●
24 25 Acceleration/deceleration switching 1 ●/● - ●●●-
26 27 Acceleration/deceleration switching 2 ●/● - ●●●-
28 29 V/f switching signal 1 ●/● - ●●● -
30 31 V/f switching signal 2 ●/● - ●●● -
32 33 Torque limit switching signal 1 ●/●●/●● ● ● -
34 35 Torque limit switching signal 2 ●/●●/●● ● ● -
36 37 PID control OFF selection ●/● - ●●●-
38 39 Pattern operation selection 1 ●/● - ●●●-
40 41 Pattern operation selection 2 ●/● - ●●●-
42 43 Pattern operation continuation signal ●/● - ●●● -
44 45 Pattern operation trigger signal ●/● - ●●●-
46 47 External thermal error ●/● - ● ● ● -
48 49 Forced switching from communication to local ●/● - ● ● ● -
50 51
Holding of HD operation (stop of three-wire
operation)
●/● - ● ● ● -
52 53 PID differentiation/integration reset ●/● - ● ● ● -
54 55 PID forward/reverse switching ●/● - ● ● ● -
56 57 Forced continuous operation ●/● - ● ● ● -
58 59 Specified speed operation ●/● - ● ● ● -
60 61 Acceleration/deceleration suspend signal ●/● - ● ● ● -
62 63 Power failure synchronized signal ●/● - ● ● ● -
64 65 My function RUN signal ●/● ●/● ● ● ● -
66 67 Auto-tuning signal ●/● - ● ● ● -
68 69 Speed gain switching ●/● - ● ● ● -
7.2.1
*1: Valid any time
*2: Independent of EOQF, and all command are valid.