[j f- , P n (Panel Control Parameters)
P cd P Acc/dec #1 and #2 selection
Related parameters
Rd3 Acc/dec #1 and #2 selection
C r.F 3 Rd3F Acc/dec #1 and #2 switching frequency
Automatic switching of the acc/dec times can be easily performed by combining the use of terminal block input
AD2, acc/dec #1 and #2 selection Rd3 > and acc/dec #1 and #2 switching frequency Rd3F
(Refer to CROd in Cr. Lit and it* in Hr. St {*: 0 to /0) for setting the terminal
block inputs.)
Time [S]
—>
* Refer to the section on command mode selection ( CROd in Cr. Ub ) for the selection of the
start/stop command.
* If the start/stop command source is selected to be the operating panel, the acc/dec will function according
to the setting of parameter Rd3 regardless of the state of terminals AD2-CC.
* If the start/stop command source is selected to be the input terminals, acceleration/deceleration #1
and #2 switching will be selected by the terminal input AD2-CC state regardless of the setting of parameter
Rd3 .
52 -